Bodet Netsilon 9 NTP Time Server, PTP Grandmaster Clock

  • Internal oscillator OCXO
  • Precision (average after 24h of GPS synchronisation) 1*10-11
  • Medium term stability (without GPS after 2 weeks of GPS synchronisation) 1*10-9/day
  • Holdover after 24h (after 2 weeks of GPS synchronisation at constant temperature) ±15 μs
  • Operating temperature From 0 °C to 50 °C
  • Dimensions 487 x 245 x 44.2 mm (19” 1 U)
  • Check Mark Note : For large projects or quantity orders, please email us for Project Pricing.
       

Description

Bodet Netsilon 9 NTP Time Server, PTP Grandmaster Clock – synchronise and secure your networks. The security of critical systems is fundamental. In the event of an outage or malfunction, the consequences can be dramatic. This is why all the structures concerned must be equipped with a reliable and autonomous time server to synchronise their equipment with precision in case of an attack. This will limit the risk of intrusion and other cyber threats.

Even more features, even more performance

Netsilon 9: more features, more performance

Customisable. Depending on your needs and the constraints of your network installation, Netsilon 9 is able to adapt to transmit time information via a wide range of protocols. Its modular design with option cards enables a wide variety of input/output signals: 1PPS, IRIG, PTP, NTP, 10 MHz.
Secure. Encryptions, single sign-on system, activation/deactivation of network protocols: these are just some of the parameters available on Bodet Netsilon 9 NTP Time Server that makes it a robust solution.
Durable. Literally and figuratively. On one hand, its fanless design ensures a longer service life. On the other hand, its low energy consumption means it uses less electricity and is therefore more respectful of the planet.

The time precision that critical systems need

Many structures need a precise timekeeping. This is particularly the case in the energy and broadcasting sectors and connected industry 4.0. Thanks to its next-generation internal OCXO oscillator*, Bodet Netsilon 9 NTP Time Server achieves micro-second accuracy to meet the network challenges of these sectors. All the information system’s equipment is synchronised via multi-source satellite reference signals: GPS, GLONASS, BeiDou, Galileo. With Netsilon 9, you can accurately trace all the events on your network. Which allows you to stay in control.

Network

Network protocol

  • NTP V2 / V3 / V4: Yes
  • SNTP V3 / V4: Yes
  • TIME + DAYTIME protocol: Yes
  • Number of NTP requests per second: 7,000

Network communication

  • HTTP / HTTPS: Yes
  • SSH v1.3 / SSH v1.5 / SSH v2 (OpenSSH): Yes

Network management and monitoring

  • IPv4 / IPv6: Yes
  • DHCPv4 / DHCPv6 (AUTOCONF / SLAAC): Yes
  • SMTP: Yes
  • SNMP v1 / v2c / v3: Yes
  • SYSLOG (UDP / TCP / TLS): Yes
  • Relay contact / External input: Yes
Bodet Netsilon 9 NTP Time Server Technical information
  • Internal oscillator OCXO
  • Precision (average after 24h of GPS synchronisation) 1*10-11
  • Medium term stability (without GPS after 2 weeks of GPS synchronisation) 1*10-9/day
  • Holdover after 24h (after 2 weeks of GPS synchronisation at constant temperature) ±15 μs
  • Operating temperature From 0 °C to 50 °C
  • Dimensions 487 x 245 x 44.2 mm (19” 1 U)
  • Power supply (without fan)
    DC : 22-30V  / 3.2-1.9A
    AC : 100-240V  / 50-60Hz / 1.9-0.8A
Dimensions of the Netsilon 9 Time Server
Bodet Netsilon 9 NTP Time Server Security
  • Activating/disabling protocols Yes
  • Single sign-on protection Yes
  • DES and AES encryptions Yes
  • SSL Encryption Yes
  • SCP Yes
  • SFTP Yes
  • LDAP / LDAPS / RADIUS authentication Yes

Bodet Netsilon 9 NTP Time Server Datasheet

Accessories

Downloads

Bodet Netsilon 9 NTP Time Server Datasheet

Related products and Accessories